Latch Lock-Z170
- Similar to HASCO’s Z170 1. mechanical interlocking design, safe and reliable.
- Insert bar, end of pull rod adopt high frequency annealing treatment, so that easy to second time processing installed holes.
- This latch parts not only control opening mold sequence, But also control closed sequence.
- Product Details
- Factory
- Application
- Please install the housing in parallel to the parting line first.
- Before install the control bar, please cut it to the necessary length, form the bolt hole. Please tighten the screw when mold closed.(Please note:Make sure in a fully position mold before fix the control bar, and eliminate the clearance between the control bar and locking roller)
- Please cut the latch bar to the necessary length, and installation in parallel to the parting line.
- Please install the latch lock symmetrically, otherwise, it would be fractured with the unbalanced force due to only one side of lockset be forced.
- This latch lock is the precise standardized item, please do not apply together with other own customer machined parts.
- If mold need to maintain, please remove the latch locks first.
- After installed, carryout a functional test, check whether the individual parts of the latch lock units moves smoothly, the stroke is applicable.Recommend testing on matched Molds machine or Injection machine,no Lifting Machine.